Cub 200/300/300 HD Maintenance
wcghi_tx000721gb.fm 39
4.11 Inspecting the Electrical Connections
After disconnecting the power cord, check all electrical connections for
the following:
Proper connections. Be sure that all connections are complete and
tight.
Corrosion. Clean or replace if necessary.
Damaged wires/connectors. Replace if necessary.
Proper ground.
4.12 Fuel Blend Guide
Fuel Blend Guide
Temperature Range
Fuel Blend
15° to 30°F 80% #2 : 20% #1
0° to 15°F 70% #2 : 30% #1
–15° to 0°F 50% #2 : 50% #1
below –15°F 30% #2 : 70% #1