Página 1 - Mobile Generator

www.wackergroup.comMobile GeneratorG 50G 70G 85OPERATOR’S MANUAL0162089en 00811070162089EN

Página 2

Safety Information G 50/G 70/G 85wc_si000158gb.fm 102.2 Service SafetyA poorly maintained machine can become a safety hazard! In orderfor the machine

Página 3 - 3. Operation 24

G 50/G 70/G 85 Safety Informationwc_si000158gb.fm 112.2.11 ALWAYS remain aware of moving parts and keep hands, feet, andloose clothing away from the m

Página 4 - 6. Technical Data 86

Safety Information G 50/G 70/G 85wc_si000158gb.fm 122.4 Towing SafetyTowing a large trailer requires special care. Both the trailer and vehiclemust be

Página 5 - Foreword

G 50/G 70/G 85 Safety Informationwc_si000158gb.fm 132.5 Reporting Trailer Safety DefectsIf you believe your trailer has a defect which could cause a c

Página 6 - 2. Safety Information

Safety Information G 50/G 70/G 85wc_si000158gb.fm 142.6 Label Location

Página 7 - Corporation

G 50/G 70/G 85 Safety Informationwc_si000158gb.fm 15

Página 8 - 2.1 Operating Safety

Safety Information G 50/G 70/G 85wc_si000158gb.fm 162.7 Safety and Operating LabelsRef. Label MeaningAB WARNING! Pressurized contents. Do not open wh

Página 9

G 50/G 70/G 85 Safety Informationwc_si000158gb.fm 17F DANGER! Asphyxiation hazard. Read the Opera-tor’s Manual for instructions. No sparks, flames, or

Página 10 - 2.2 Service Safety

Safety Information G 50/G 70/G 85wc_si000158gb.fm 18LM Operator’s Manual must be stored on machine. Replacement Operator’s Manual can be ordered throu

Página 11

G 50/G 70/G 85 Safety Informationwc_si000158gb.fm 19O WARNING! Generator can automatically start which can cause serious injury. Disconnect battery be

Página 13

Safety Information G 50/G 70/G 85wc_si000158gb.fm 20T WARNING! Disconnect battery before servicing.Read the Operator's Manual.UV Operator’s Manua

Página 14 - 2.6 Label Location

G 50/G 70/G 85 Safety Informationwc_si000158gb.fm 21Z Neutral bonded to frame.AA FusesRead the operator's manual for machine information.1 - Cont

Página 15

Safety Information G 50/G 70/G 85wc_si000158gb.fm 22DD G 50 / G 70 - Engine WiringG 70 w/ECU & G 85 - Engine WiringEE WARNING! Hot surface!FF A na

Página 16 - INSTRUCTIONS DE REMORQUAGE

G 50/G 70/G 85 Safety Informationwc_si000158gb.fm 23GG CAUTION: Do not use battery disconnect switch while engine is running. Damage to electrical com

Página 17

Operation G 50/G 70/G 85wc_tx000483gb.fm 243. Operation3.1 Control Panels

Página 18

G 50/G 70/G 85 Operationwc_tx000483gb.fm 25Ref. Description Ref. Descriptiona Main Circuit Breaker l Twist-Lock Receptacle(120/240 VAC, 50Amp) - twob

Página 19 - DEMARRAGE A

Operation G 50/G 70/G 85wc_tx000483gb.fm 263.2 Generator MonitoringGenerator information is displayed on the top line of the LCD panel andis scrolled

Página 20 - L1 L2 L3

G 50/G 70/G 85 Operationwc_tx000483gb.fm 273.3 Engine MonitoringWith the engine start switch set to “RUN/START” or “REMOTESTART”, engine information w

Página 21

Operation G 50/G 70/G 85wc_tx000483gb.fm 283.4 Engine Shutdown FaultsThe engine control module (ECM) continuously monitors vital enginefunctions for f

Página 22

G 50/G 70/G 85 Operationwc_tx000483gb.fm 293.5 Current Overload FaultAlong with engine functions the ECM continuously monitors the currentload in each

Página 23 - PRECAUTION

G 50/G 70/G 85 Table of Contentswc_bo0162089en_008TOC.fm 31. Foreword 52. Safety Information 62.1 Operating Safety ...

Página 24 - Operation G 50/G 70/G 85

Operation G 50/G 70/G 85wc_tx000483gb.fm 303.7 Voltage Selector SwitchSee Graphic: wc_gr001682The voltage selector switch is located in a separate enc

Página 25 - G 50/G 70/G 85 Operation

G 50/G 70/G 85 Operationwc_tx000483gb.fm 313.8 Emergency Stop SwitchSee Graphic: wc_gr001677The emergency stop switch (p) is the red button located b

Página 26

Operation G 50/G 70/G 85wc_tx000483gb.fm 323.9 Main Line Circuit BreakerSee Graphic: wc_gr002611The main line circuit breaker (a) is located on the co

Página 27

G 50/G 70/G 85 Operationwc_tx000483gb.fm 333.10 Engine Start SwitchSee Graphic: wc_gr002611The engine start switch (f) is a three-position switch: “RE

Página 28

Operation G 50/G 70/G 85wc_tx000483gb.fm 343.13 Connection LugsSee Graphic: wc_gr002611The customer connection lugs (r) are located on left at the bot

Página 29 - LOW WATER LEVEL

G 50/G 70/G 85 Operationwc_tx000483gb.fm 353.14 Ground ConnectionSee Graphic: wc_gr002611A ground connection (s) is located next to the terminal lugs.

Página 30

Operation G 50/G 70/G 85wc_tx000483gb.fm 363.18 Terminal ConnectionsALL CONNECTIONS TO THE TERMINALS MUST BE MADE BY ATRAINED ELECTRICIAN. BACKFEED FR

Página 31

G 50/G 70/G 85 Operationwc_tx000483gb.fm 373.19 Before StartingBefore putting the generator into service, review each item on thefollowing checklist.

Página 32

Operation G 50/G 70/G 85wc_tx000483gb.fm 383.20 Manual Start-upSee Graphic: wc_gr001682, wc_gr001677, wc_gr002611Before starting the generator set, th

Página 33

G 50/G 70/G 85 Operationwc_tx000483gb.fm 393.20.7 After engine starts, allow it to warm up for a few minutes and checkreadouts on LCD panel. The “TIM

Página 34

Table of Contents G 50/G 70/G 85wc_bo0162089en_008TOC.fm 43.28 Automatic/Remote Start-up ...

Página 35

Operation G 50/G 70/G 85wc_tx000483gb.fm 403.21 Running the GeneratorSee Graphic: wc_gr002611Leave the Engine Start Switch (f) in the “START/RUN” posi

Página 36

G 50/G 70/G 85 Operationwc_tx000483gb.fm 413634323028262422201816141210 8 6 4 2 078 9 1011121314 15 161718(2,1) (2,4) (2,75) (3,0) (3,3) (3,6) (4,0) (

Página 37

Operation G 50/G 70/G 85wc_tx000483gb.fm 423.23 Shutting Down GeneratorCheck with other personnel on the jobsite and let them know thatpower is being

Página 38

G 50/G 70/G 85 Operationwc_tx000483gb.fm 433.28 Automatic/Remote Start-upSee Graphic: wc_gr002611In the “REMOTE START” position the generator can be s

Página 39

Operation G 50/G 70/G 85wc_tx000483gb.fm 443.29 Remote/Transfer SwitchSee Graphic: wc_gr002611When the generator is used as a standby power supply, it

Página 40

G 50/G 70/G 85 Operationwc_tx000483gb.fm 453.30 TowingSee Graphic: wc_gr000510The generator trailer is equipped with brakes, lights, and couplerconnec

Página 41

Operation G 50/G 70/G 85wc_tx000483gb.fm 46w c _ g r 0 0 0 5 1 0adc b

Página 42

G 50/G 70/G 85 Maintenancewc_tx000484gb.fm 474. Maintenance4.1 Periodic Maintenance ScheduleThe Periodic Maintenance Schedule below lists basic mainte

Página 43

Maintenance G 50/G 70/G 85wc_tx000484gb.fm 484.2 New Machines4.2.1 Run generator at least 60–100% of continuous load for the first 100hours.4.2.2 Chan

Página 44

G 50/G 70/G 85 Maintenancewc_tx000484gb.fm 494.4 Air CleanerSee Graphic: wc_gr000511Replace the air filter cartridge when yellow indicator of the engi

Página 45

Forewordwc_tx000001gb diesel.fm 51 ForewordThis manual provides information and procedures to safely operateand maintain this Wacker model. For your o

Página 46

Maintenance G 50/G 70/G 85wc_tx000484gb.fm 504.5 Engine LubricationCheck engine oil daily before starting engine. DO NOT operate engine if oil level i

Página 47 - G 50/G 70/G 85 Maintenance

G 50/G 70/G 85 Maintenancewc_tx000484gb.fm 514.6 Engine CoolantCheck the coolant level of the radiator with the engine cold. After initialfilling of r

Página 48 - Maintenance G 50/G 70/G 85

Maintenance G 50/G 70/G 85wc_tx000484gb.fm 524.8 Troubleshooting Automatic ShutdownThere are several automatic shutdown conditions: low oil pressure,h

Página 49

G 50/G 70/G 85 Maintenancewc_tx000484gb.fm 53Overspeed or Underspeed ShutdownRestart engine and read the AC frequency meter. Meter should read60 Hz un

Página 50

Maintenance G 50/G 70/G 85wc_tx000484gb.fm 544.10 Generator and Receptacle WiringBOM Revision See Graphic:Revision See Graphic:Revision See Graphic:00

Página 51

G 50/G 70/G 85 Maintenancewc_tx000484gb.fm 55RECTIFIERRECTIFIERROTORROTORSTATORSTATORRY (+)Y (+)V5C5C5B5BW65A5A543A3A34A4A7AMPAMPSTABSTABVOLTVOLTHZHZL

Página 52

Maintenance G 50/G 70/G 85wc_tx000484gb.fm 56BOM Revision See Graphic:Revision See Graphic:Revision See Graphic:0009366 123 & higher wc_gr004692 1

Página 53 - Wire Colors

G 50/G 70/G 85 Maintenancewc_tx000484gb.fm 57

Página 54

Maintenance G 50/G 70/G 85wc_tx000484gb.fm 58BOM Revision See Graphic:Revision See Graphic:Revision See Graphic:0009366 123 & higher wc_gr004692 1

Página 55

G 50/G 70/G 85 Maintenancewc_tx000484gb.fm 59

Página 56

Safety Information G 50/G 70/G 85wc_si000158gb.fm 62. Safety InformationThis manual contains DANGER, WARNING, CAUTION, NOTICE andNOTE callouts which m

Página 57

Maintenance G 50/G 70/G 85wc_tx000484gb.fm 604.11 Trailer WiringRef. Description1 Front right side amber light2 Front left side amber light3 Trailer p

Página 58

G 50/G 70/G 85 Maintenancewc_tx000484gb.fm 61Standard and Hydraulic BrakesElectric Brakes                   

Página 59

Maintenance G 50/G 70/G 85wc_tx000484gb.fm 624.12 G 50/G 70 Engine WiringEngineWiresBOM Revision See Graphic:RevisionSee Graphic:Rev. See Graphic:Revi

Página 60

G 50/G 70/G 85 Maintenancewc_tx000484gb.fm 63G 50/G 70 Engine Wiring4646GROUND TOGROUND TOENCLOSURE ENCLOSURE BOX STUDBOX STUD79794747R121213131111868

Página 61

Maintenance G 50/G 70/G 85wc_tx000484gb.fm 64EngineWiresBOM Revision See Graphic:RevisionSee Graphic:Rev. See Graphic:RevisionSee Graphic:0009366 123

Página 62

G 50/G 70/G 85 Maintenancewc_tx000484gb.fm 65G 50/G 70 Engine Wiring

Página 63

Maintenance G 50/G 70/G 85wc_tx000484gb.fm 66EngineWiresBOM Revision See Graphic:RevisionSee Graphic:Rev. See Graphic:RevisionSee Graphic:0009366 123

Página 64

G 50/G 70/G 85 Maintenancewc_tx000484gb.fm 67G 50/G 70 Engine Wiring

Página 65

Maintenance G 50/G 70/G 85wc_tx000484gb.fm 68EngineWiresBOM Revision See Graphic:RevisionSee Graphic:Rev. See Graphic:RevisionSee Graphic:0009366 123

Página 66

G 50/G 70/G 85 Maintenancewc_tx000484gb.fm 69G 50/G 70 Engine Wiring

Página 67

G 50/G 70/G 85 Safety Informationwc_si000158gb.fm 7This machine is built with user safety in mind; however, like anyelectrical device it can present s

Página 68

Maintenance G 50/G 70/G 85wc_tx000484gb.fm 704.13 G 85 & G 70 w/ECU Engine WiringEngineWiresBOM Revision See Graphic: Revision See Graphic:0009369

Página 69

G 50/G 70/G 85 Maintenancewc_tx000484gb.fm 71G 85 & G 70 w/ECU Engine Wiring14 14 B B B-+ R RORORORORB+B+D+D+B+B+N2N21212R1111868685853030B1313G

Página 70

Maintenance G 50/G 70/G 85wc_tx000484gb.fm 72EngineWiresBOM Revision See Graphic: Revision See Graphic:0009369 124 & higher wc_gr004614 123 &

Página 71

G 50/G 70/G 85 Maintenancewc_tx000484gb.fm 73

Página 72

Factory-Installed Options Mobile Generatorswc_tx000380gb.fm 745 Factory-Installed OptionsThis machine may be equipped with one or more of the followin

Página 73

Mobile Generators Factory-Installed Optionswc_tx000380gb.fm 755.2 Fuel/Water Separator See Graphic: wc_gr001705The fuel/water separator separates wate

Página 74 - 5.1 Block Heater

Factory-Installed Options Mobile Generatorswc_tx000380gb.fm 765.3 Electronic GovernorSee Graphic: wc_gr001714, wc_gr001715, wc_gr001716, wc_gr001717Th

Página 75 - 5.2 Fuel/Water Separator

Mobile Generators Factory-Installed Optionswc_tx000380gb.fm 775.4 LCD Strip HeaterSee Graphic: wc_gr001724, wc_gr001725The LCD strip heater option inc

Página 76 - 5.3 Electronic Governor

Factory-Installed Options Mobile Generatorswc_tx000380gb.fm 785.5 Low Coolant ShutdownSee Graphic: wc_gr001708The low-coolant shutdown system consists

Página 77 - 5.4 LCD Strip Heater

Mobile Generators Factory-Installed Optionswc_tx000380gb.fm 795.6 Lube Level MaintainerSee Graphic: wc_gr001711, wc_gr001712, wc_gr001713The lube leve

Página 78 - 5.5 Low Coolant Shutdown

Safety Information G 50/G 70/G 85wc_si000158gb.fm 82.1 Operating SafetyFamiliarity and proper training are required for the safe operation of themachi

Página 79 - 5.6 Lube Level Maintainer

Factory-Installed Options Mobile Generatorswc_tx000380gb.fm 805.7 Temperature-Activated ShuttersSee Graphic: wc_gr001706, wc_gr001707The shutters (a)

Página 80

Mobile Generators Factory-Installed Optionswc_tx000380gb.fm 81Notes:

Página 81

Factory-Installed Options Mobile Generatorswc_tx000380gb.fm 825.9 Wiring Diagram Wire ColorsB Black R Red Y Yellow Or OrangeG Green T Tan Br Brown Pr

Página 82

Mobile Generators Factory-Installed Optionswc_tx000380gb.fm 835.10 Wiring Diagram ComponentsSee Graphic: wc_gr001868 Ref Description Ref Descriptio

Página 83

Factory-Installed Options Mobile Generatorswc_tx000380gb.fm 845.11 Cam-LockSee Graphic: wc_gr002584A second optional outlet panel features cam-lock co

Página 84 - 5.11 Cam-Lock

Mobile Generators Factory-Installed Optionswc_tx000380gb.fm 855.12 Containment SystemSee Graphic: wc_gr002647Overspills and leaks are captured in the

Página 85 - 5.12 Containment System

Technical Data G50 /G 70/G 85866. Technical Data6.1 Engine DataItem Number:G 50000936600094670620001Rev.112 & lowerG 70000936700094680620002 Rev.1

Página 86 - Technical Data G50 /G 70/G 85

G50 /G 70/G 85 Technical Data87Item Number:G 500620001 Rev.113 & aboveG 700620002 Rev.114 & aboveG 700620351G 850620003 Rev.115 & aboveEng

Página 87 - G50 /G 70/G 85 Technical Data

Technical Data G50 /G 70/G 85886.2 Generator DataItem Number:G 50000936600094670620001G 70000936700094680620002G 70062035006203510620352G 850009369000

Página 88

G50 /G 70/G 85 Technical Data896.3 Trailer and Skid Data Item Number:G 500009366G 5000094670620001G 700009367G 7000094680620002G 700620350G 7006203

Página 89

G 50/G 70/G 85 Safety Informationwc_si000158gb.fm 92.1.17 ALWAYS keep the area immediately surrounding and underneath themachine clean, neat, and free

Página 90

Technical Data G50 /G 70/G 85906.4 Dimensionsmm (inches)

Página 92

Wacker Construction Equipment AG · Preußenstraße 41 · D-80809 München · Tel.: +49-(0)89-3 54 02 - 0 · Fax: