520000318401 05125200003184Operator’s ManualPortable GeneratorGP 2500AEN
wc_si000706gb.fm10Safety Information GP 2500Safety devices, controls, and attachmentsOnly operate the machine when: All safety devices and guards ar
wc_si000706gb.fm11GP 2500 Safety InformationTransporting and installing the machine Never allow untrained personnel to operate or service the generat
wc_si000706gb.fm12Safety Information GP 25001.4 Operator Safety while Using Internal Combustion EnginesRefueling safetyWhen refueling the engine: Do
wc_si000706gb.fm13GP 2500 Safety Information1.5 Service SafetyService trainingBefore servicing or maintaining the machine: Read and understand the in
wc_si000706gb.fm14Safety Information GP 2500Cleaning When cleaning and servicing the machine: Keep the machine clean and free of debris such as leav
GP 2500A Labelswc_si000611gb.fm 152 Labels2.1 Label Locations2.2 Label MeaningsWacker Neuson machines use international pictorial labels where needed.
Labels GP 2500A16 wc_si000611gb.fmCDANGERUsing a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust co
GP 2500A Labelswc_si000611gb.fm 17—Turn the engine switch to the ON position.—Pull the rewind starter.—Open the choke.—Turn the engine switch to “OFF”
Labels GP 2500A18 wc_si000611gb.fmGImportant Emissions InformationThis equipment meets California EVP emis-sion
GP 2500A Lifting and Transportingwc_tx001858gb.fm 193 Lifting and TransportingLifting the MachineThis generator, while compact, is heavy enough to cau
Copyright notice© Copyright 2012 by Wacker Neuson Production Americas LLCAll rights, including copying and distribution rights, are reserved.This publ
Operation GP 2500A20 wc_tx000447gb.fm4 Operation4.1 Preparing the Machine for First UsePreparing for first useTo
GP 2500A Operationwc_tx000447gb.fm 214.2 Refueling the MachineRequirements• Machine shut down• Engine cool• Machine/fuel tank level with the ground• F
Operation GP 2500A22 wc_tx000447gb.fm4.3 Determining Power RequirementsThis generator is designed to operate sin
GP 2500A Operationwc_tx000447gb.fm 234.5 Generator DeratingAll generators are subject to derating for altitude and temperature.Internal combustion eng
Operation GP 2500A24 wc_tx000447gb.fm4.6 Grounding the GeneratorLocationA ground connection (a) is located on th
GP 2500A Operationwc_tx000447gb.fm 254.8 Use of Extension CordsWhen a long extension cord is used to connect an appliance or tool tothe generator, a v
Operation GP 2500A26 wc_tx000447gb.fm4.9 Control PanelRef. Description Ref. Descriptiona GFI duplex receptacle—1
GP 2500A Operationwc_tx000447gb.fm 274.10 Ground Fault Interrupt (GFI / GFCI)The 120V, 20 Amp receptacle (a) is equipped with a ground fault circuitin
Operation GP 2500A28 wc_tx000447gb.fm4.12 Before Starting4.12.1 Read and understand the safety and operating lab
GP 2500A Operationwc_tx000447gb.fm 294.13 Starting4.13.1 Ensure that the generator is properly installed in an outdoor location.See Sections Installat
Forewordwc_tx001857gb.fm 3ForewordSAVE THESE INSTRUCTIONS—This manual contains important instructions for the machine models listed below. These instr
Operation GP 2500A30 wc_tx000447gb.fm4.15 Emergency Shutdown ProcedureProcedureIf a breakdown or accident occurs
GP 2500A Maintenancewc_tx000448gb.fm 315 Maintenance5.1 Maintaining the Emission Control SystemNormal maintenance, replacement, or repair of emission
Maintenance GP 2500A32 wc_tx000448gb.fm5.3 Engine Oil5.3.1 Drain the oil while the engine is still warm.5.3.2 Re
GP 2500A Maintenancewc_tx000448gb.fm 335.4 Servicing the Air CleanerService the air cleaner frequently to prevent carburetor malfunction. NOTICE: NEVE
Maintenance GP 2500A34 wc_tx000448gb.fm5.5 Spark PlugClean or replace the spark plug as needed to ensure proper
GP 2500A Maintenancewc_tx000448gb.fm 355.6 Cleaning the Sediment Cup5.6.1 Turn the fuel valve off. 5.6.2 Remove the sediment cup (a) and the O-ring (b
Maintenance GP 2500A36 wc_tx000448gb.fm5.7 Adjusting the Carburetor5.7.1 Start the engine and allow it to warm u
GP 2500A Maintenancewc_tx000448gb.fm 375.9 Long-Term StorageBefore storing the generator for a long period of time:5.9.1 Close the fuel valve and remo
GP 2500A38 wc_tx001859gb.fm6 Troubleshooting Problem / Symptom Reason / RemedyIf engine doesn't start, chec
GP 2500A Technical Datawc_td000190gb.fm 397 Technical Data7.1 GeneratorItem No. GP 2500AGeneratorMaximum OutputW2500Continuous OutputW2250Type Single
Foreword4 wc_tx001857gb.fmManufacturer’s approvalThis manual contains references to approved parts, attachments,
Technical Data GP 2500A40 wc_td000190gb.fm7.2 EngineEngine Power RatingNet power rating per SAE J1349. Actual po
GP 2500A Technical Datawc_td000190gb.fm 41Notes:
Schematics GP 2500A42 wc_tx001860gb.fm8 Schematics8.1 Wire Colors8.2 Electrical Schematic Components Wire Col
GP 2500A Schematicswc_tx001860gb.fm 438.3 Electrical Schematic811910
Schematics GP 2500A44 wc_tx001860gb.fm
Emission Control Systems Information and Warrantywc_tx001772gb.fm459 Emission Control Systems Information and WarrantyThe Emission Control Warranty an
Emission Control Systems Information and Warranty46 wc_tx001772gb.fmTampering and AlteringTampering with or alte
Emission Control Systems Information and Warrantywc_tx001772gb.fm47the part in question is not related to the reason the engine/equipment requires rep
Emission Control Systems Information and Warranty48 wc_tx001772gb.fmcoverage solely for the lack of receipts or
Emission Control Systems Information and Warrantywc_tx001772gb.fm499.4 California Evaporative Emission Control Warranty StatementYour Warranty Rights
wc_bo5200003184_01TOC.fm 5Table of ContentsGP 2500AForeword 31 Safety Information 71.1 Signal Words Used in this Manual ...
Emission Control Systems Information and Warranty50 wc_tx001772gb.fmAll failures caused by abuse, neglect, or im
Wacker Neuson Produktion GmbH & Co. KG, Preußenstraße 41, D-80809 München, Tel.: +49-(0)89-3 54 02-0 Fax: +49 - (0)89-3 54 02-390Wacker N
6 wc_bo5200003184_01TOC.fmTable of ContentsGP 2500A5 Maintenance 315.1 Maintaining the Emission Control System .
wc_si000706gb.fm7GP 2500 Safety Information1 Safety Information1.1 Signal Words Used in this ManualThis manual contains DANGER, WARNING, CAUTION, NOTI
wc_si000706gb.fm8Safety Information GP 25001.2 Machine Description and Intended UseThis machine is a portable electric power source. The Wacker Neuso
wc_si000706gb.fm9GP 2500 Safety Information1.3 Operating SafetyOperator trainingBefore operating the machine: Read and understand the operating instr
Comentários a estes Manuais