Resumo do Conteúdo

Página 1 - GP 2500A

GeneratorGP 2500AOPERATOR’S MANUAL0163727en 00505090163727EN

Página 2 - CARBON MONOXIDE

Safety Information GP 2500A101.3 Operator Safety while using Internal Combustion EnginesInternal combustion engines present special hazards during ope

Página 3 - Foreword

GP 2500A Safety Information111.4 Service SafetyPoorly maintained equipment can become a safety hazard! In orderfor the equipment to operate safely an

Página 4

Safety Information GP 2500A121.5 Label Locations GND8889711223456

Página 5 - GP 2500A Table of Contents

GP 2500A Safety Information131.6 Safety and Operating LabelsWacker Neuson machines use international pictorial labels whereneeded. These labels are de

Página 6 - Table of Contents GP 2500A

Safety Information GP 2500A14WARNING! To reduce the risk of electrical shock and arc flash, read the Operator’s Manual. Improper connection of the ge

Página 7

GP 2500A Safety Information15Open the fuel flow valve.Close the choke.Turn the engine switch to the ON position.Pull the rewind starter.Open the choke

Página 8

Safety Information GP 2500A16This equipment does not meet California EVP emission regulations for small off-road engines.A nameplate listing the model

Página 9

GP 2500A Operation172. Operation2.1 Determining Power RequirementsThis generator is designed to operate single-phase, 60 Hz appliancesrunning at 120 V

Página 10 - Safety Information GP 2500A

Operation GP 2500A182.2 InstallationPlace the generator in an area where it will not be exposed to rain,snow, or direct sunlight. Make sure it is posi

Página 11 - GP 2500A Safety Information

GP 2500A Operation192.3 Generator DeratingAll generators are subject to derating for altitude and temperature.Internal combustion engines, unless modi

Página 12

DANGERCARBON MONOXIDEUsing a generator indoors CAN KILL YOU IN MINUTES.Generator exhaust contains carbon

Página 13

Operation GP 2500A202.4 Grounding the GeneratorA ground connection (a) is located on the generator frame. For properoperating safety, this ground term

Página 14

GP 2500A Operation212.6 Use of Extension CordsWhen a long extension cord is used to connect an appliance or tool tothe generator, a voltage loss occur

Página 15

Operation GP 2500A222.7 Control PanelRef. Description Ref. Descriptiona GFI duplex receptacle—120V d GFI test buttonb Circuit breaker—20 Amp. e GFI re

Página 16

GP 2500A Operation232.8 Ground Fault Interrupt (GFI)The 120V, 20 Amp receptacle (a) is equipped with a ground fault circuitinterrupt (GFI). The GFI sh

Página 17 - GP 2500A Operation

Operation GP 2500A242.10 Before Starting2.10.1 Read and understand the safety and operating labels and instructionsat the beginning of this manual.2.1

Página 18 - Operation GP 2500A

GP 2500A Operation252.11 To Start2.11.1 Ensure that the generator is properly installed in an outdoor location.See Sections Installation and Operator

Página 19

Maintenance GP 2500A263. Maintenance3.1 Engine MaintenanceThe chart below lists basic machine and engine maintenance. Refer toyour engine operator’s m

Página 20

GP 2500A Maintenance273.3 Engine Oil3.3.1 Drain the oil while the engine is still warm.3.3.2 Remove the oil filler plug (a) and the drain plug (b) to

Página 21

Maintenance GP 2500A283.4 Servicing Air CleanerService the air cleaner frequently to prevent carburetor malfunction. NOTICE: NEVER run the engine with

Página 22

GP 2500A Maintenance293.5 Spark PlugClean or replace the spark plug as needed to ensure proper operation.Refer to your engine operator’s manual. T

Página 23

wc_tx000001gb.fm 3CALIFORNIAProposition 65 Warning: Engine exhaust, some of its constituents, and certain vehiclecomponents, contain or emit chemical

Página 24

Maintenance GP 2500A303.6 Cleaning the Sediment Cup3.6.1 Turn the fuel valve off. 3.6.2 Remove the sediment cup (a) and the O-ring (b). 3.6.3 Wash bot

Página 25

GP 2500A Maintenance313.7 Carburetor Adjustment3.7.1 Start the engine and allow it to warm up to operating temperature.3.7.2 Set the pilot screw (a) t

Página 26 - Maintenance GP 2500A

Maintenance GP 2500A323.8 Adjusting Engine SpeedGenerators require a fixed engine speed to maintain the correctvoltage. Engine speed is controlled by

Página 27 - GP 2500A Maintenance

GP 2500A Maintenance333.10 Transport Let the engine cool before transporting the generator or storing itindoors, to avoid burns or fire hazards.When t

Página 28

Maintenance GP 2500A343.12 Wire Colors3.13 Wiring Schematic Wire ColorsB Black R Red Y Yellow Or OrangeG Green T Tan Br Brown Pr PurpleL Blue V Vio

Página 29

GP 2500A Maintenance35811910

Página 30

Technical Data GP 2500A364. Technical Data4.1 GeneratorItem No. GP 2500A0620128GeneratorMaximum OutputW2500Continuous OutputW2250Type Single voltage,

Página 31

GP 2500A Technical Data374.2 EngineEngine Power RatingNet power rating per SAE J1349. Actual power output may vary due toconditions of specific use.It

Página 32

Wacker Neuson SE · Preußenstraße 41 · D-80809 München · Tel.: +49-(0)89-3 54 02-0 · Fax: +49 - (0)89-3 54 0

Página 33

wc_tx000001gb.fm 4

Página 34 - Wire Colors

GP 2500A Table of Contents5Foreword 31 Safety Information 71.1 Laws Pertaining to Spark Arresters ...

Página 35

Table of Contents GP 2500Awc_bo0163727en_005TOC.fm 63 Maintenance 263.1 Engine Maintenance ...

Página 36 - Technical Data GP 2500A

GP 2500A Safety Information71. Safety InformationThis manual contains DANGER, WARNING, CAUTION, NOTICE, andNOTE callouts which must be followed to red

Página 37 - GP 2500A Technical Data

Safety Information GP 2500A81.2 Operating SafetyUsing a generator indoors CAN KILL YOU IN MINUTES. Generatorexhaust contains carbon monoxide. This is

Página 38

GP 2500A Safety Information91.2.8 NEVER allow untrained personnel to operate or service the generator.The generator set should be set up by a certifie