Wacker Neuson GPS 5600A Manual do Operador Página 16

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 50
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 15
GP/GPS 5600A Safety Information
16
DANGER!
No sparks, flames or burning objects near
machine.
Shut off the engine before refueling.
Read the Operator’s Manual for machine
information.
GFCI TEST INSTRUCTIONS - TEST BEFORE EACH USE
Normal operating state - sensing device green LED is "ON" and circuit breaker is at "ON"
position.
Step 1: Press "TEST" button. Green LED should go "OUT" and red LED should come
"ON" and circuit breaker should trigger to "OFF" position.
Step 2: If sensing device LED or breaker does not trip or change state, "DO NOT USE".
Consult an electrician for assistance.
Step 3: Press "RESET" button. Red LED should turn "OFF" and green LED should turn
"ON".
Step 4: Manually reset (switch) circuit breaker to "ON" position to restore circuit power.
Label Meaning
Vista de página 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 49 50

Comentários a estes Manuais

Sem comentários